Description
NGP 884B/SS 60″ Extended Threshold Bumper Edge, 7/8″ x 2″
NGP 884B/SS 60″ Extended Width Threshold Bumper Edge, 7/8″ x 2″ is a robust solution designed for commercial restroom partitions. Constructed from aluminum alloy 6063 with T5 temper, this bumper edge is built to withstand the rigors of high-traffic environments while providing reliable protection and durability. Measuring 2″ wide and 7/8″ tall, it effectively covers gaps and prevents damage to your walls and doors. Weighing only .48 lbs./ft., the NGP 884B/SS is lightweight yet sturdy, making installation straightforward. The product comes with #10 x 1-1/2″ FH zinc-plated wood screws, ensuring a secure fit for long-lasting performance. Its mill finish offers a clean, modern look, while the black silicone adds a functional touch. This threshold bumper edge meets rigorous safety standards, certified by UL to CAN/ULC-S104 and ANSI/UL10B, and complies with NFPA 80 for fire doors. It is also air infiltration tested to ASTM E283, enhancing your building’s energy efficiency. Designed to ship via UPS, the NGP 884B/SS is an excellent choice for anyone looking to enhance the functionality and safety of their restroom partitions.
60″ Extended Width Threshold Bumper Edge, 7/8″ x 2″
- #10 x 1-1/2″ FH zinc plated wood screws included. Dark bronze supplied with DKB thresholds
- Mill finish
- 2″ wide x 7/8″ tall
- Typical Wall Thickness: .110″
- Silicone is black
- Aluminum alloy 6063, T5 temper
- Weight: .48 lbs./ft.
Attributes
Color: Silicone is black
Dimensions: 2″ wide x 7/8″ tall
Fasteners: #10 x 1-1/2″ FH zinc plated wood screws included. Dark bronze supplied with DKB thresholds
Finish: Mill finish
Length: 60.0″
Material: Aluminum alloy 6063, T5 temper
Standard-0: CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-1: POSITIVE PRESSURE – CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
Standard-2: AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
Wall Thickness: Typical Wall Thickness: .110″
Weight: Weight: .48 lbs./ft.
Resources
- ADA Compliant Ramps
- ANSI/BHMA Certified Thresholds
- ANSI/BHMA Certified Thresholds
- Anodized vs. Mill Finish
- BHMA Standards
- Buy American
- EPDs
- Edge Sealing Systems for Positive Pressure Fire Door Assemblies
- Finger Guard 2248
- Gap Explained Sheet
- Gap Explained Sheet
- Hinge Side Finger Guard 2252
- IBC Code Revision to Fire Rated Glass in Doors
- Leed
- NGP Sustainability Report
- Returned Closed Ends for Thresholds & Ramps
- The Bad Boy Thresholds
- Thresholds Catalog
- Warranty






Reviews
There are no reviews yet.