Description
Sargent 12-55-56-8715F-ETL-10BE LHR 36X84 8700 Series Fire Rated SVR Exit Device, RX MELR, Non-Keyed, LHR, 36″x84″
Sargent 12-55-56-8715F-ETL-10BE LHR 36X84 KIT is a robust fire-rated exit device designed to enhance security in commercial spaces. Part of the esteemed 8700 Series, this Surface Vertical Rod (SVR) device offers exceptional durability, exceeding ANSI/BHMA grade 1 standards for strength and cycle performance. The kit features factory-installed Request to Exit (RX) and Motorized Electric Latch Retraction (MELR), ensuring seamless operation. Ideal for both single and double door applications, this device accommodates wood or metal doors with a minimum thickness of 1-3/4 inches. The two-point latching system, adjustable through the center case, provides reliable locking at both the top and bottom. The non-keyed passage lever trim remains operable at all times, enhancing accessibility. With a sleek dark oxidized bronze finish (613E/10BE), the Sargent exit device is not only functional but also aesthetically pleasing. Each kit includes standard mounting fasteners, ensuring easy installation. Additionally, the UL10C and UL305 listings affirm its reliability for fire and panic scenarios, making it a trusted choice for safety-conscious professionals. Upgrade your building’s security with the Sargent 12-55-56-8715F-ETL-10BE, delivering peace of mind without compromising on style or functionality.
KIT – Fire Rated, 8700 Series SVR (Surface Vertical Rod) Exit Device, Factory Installed RX and MELR (Request to Exit) and (Motorized Electric Latch Retraction), Passage Lever Trim (Trim Always Operable), Non-Keyed, Escutcheon with L Lever, LHR Left Hand Reverse, 36in x 84in, Grade 1, 613E/10BE Dark Oxidized Bronze
Notice: The info below is not item specific.
The 80 series exit device is ideal for environments that require strong and durable security solutions. Made to last the lifetime of the building, this device easily exceeds ANSI/BHMA grade 1 requirements for cycle and strength and is available in rim, mortise, surface vertical and concealed vertical rod configurations. With a modular design, this device has been crafted to be maintenance-free and provide unsurpassed security for any facility. Plus, options are available for unique applications – including delayed egress, alarmed exit and electric latch retraction – making this the go-to product for your building.
Features:
- Two point latching (top & bottom with adjustability through center case)
- Standard bottom latch compatible with latch track thresholds (by others)
- Single and double door applications
- ANSI/BHMA A156.3 – grade 1
- UL10C (Fire) and UL305 (panic) Listed
- Also available as HC8700 for hurricane-resistant applications
- Also available as FM8700, use with StormPro series doors, frames and hinges is required when used as a certified tornado solution.
- Rods are 1/2″ (13mm) brass, bronze or stainless steel
Functions:
- 06: Key unlocks trim, trim retracts latch/trim relocks when key is removed #41 cylinder supplied. ANSI 09
- 10: No outside operation (no Cylinder). ANSI 01
- 10: No outside operation (no Cylinder) ET control is used as pull only. ANSI 02
- 13: Key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
- 15: Passage only (no cylinder). ANSI 14
- 40: Freewheeling trim – no outside operation (no cylinder) dummy trim. ANSI 02
- 43: Freewheeling trim – key outside unlocks/locks trim #41 cylinder supplied. ANSI 08
- 46: Freewheeling trim – Key unlocks trim, trim retracts latch/relocks when key is removed #41 cylinder supplied. ANSI 09
- 73: Electrified ET trim – fail safe power off, unlocks lever (no cylinder)
- 74: Electrified ET trim – fail secure power off, locks lever (no cylinder)
Specifications:
- Door Type: Wood or metal doors
- Door Thickness: 1-3/4″ (44mm) minimum thickness. For doors over 1-3/4″ to 5″ thick, specify thickness and order as 31-
- Stile: 4-1/2″ (114mm) minimum stile width with trim and 3-1/2″ (44mm) minimum stile without trim
- Rail sizes as determined by door width:
- E Rail for 24″ to 32″ door widths, no cutting required for 32″ door
- F Rail for 33″ to 36″ door widths, no cutting required for 36″ door
- J Rail for 37″ to 42″ door widths, no cutting required for 42″ door
- G Rail for 43″ to 48″ door widths, no cutting required for 48″ door
- Strike: 646 Top strike (panic and fire rated), 624 bottom strike; 655 fire rated bottom strike
- Dogging Feature: Hex key dogging standard on non fired rated devices; specify 16- for cylinder dogging (#41 cylinder supplied)
- Electric Options:
- AL: Alarm
- PL: SARGuide photoluminescent coated
- 53: LX Latchbolt monitor
- 54: Outside lever monitoring
- 55: Request-to-exit signal – rail monitoring
- 56: ELR Remote latch retraction
- 58: Electric dogging
- 59: Electroguard – self contained delayed egress
- Mounting Fasteners: Supplied standard with wood and machine screws. Available with through-bolts and mortise (sex) nuts
- Top & Bottom Bolt: Brass, stainless steel
- Device Centerline from: 41″ (1041 mm) for standard applications; 38″(965mm) for elementary schools
- Door/Opening Height: Must be specified – 120″ (3048mm) max door opening – non-fire rated doors. 96″ (2438mm) max door opening – fire rated doors
- Center Case Dimensions: 8-3/8″ (213mm) x 2-5/8″ (67mm)
- Projection: Push bar neutral – 3″ (76mm), push bar depressed – 2-1/8″ (54mm)
Finishes:
- 0-3/605 – Bright brass, clear coated
- 0-4/606 – Satin brass, clear coated
- 0-9/611 – Bright bronze, clear coated
- 1-0/612 – Satin bronze, clear coated
- 10B/613 – Dark oxidized satin bronze, oil rubbed
- 10BE/613E – Dark oxidized satin bronze, equivalent
- 10BL/613L – Dark oxidized satin bronze clear coated
- 1-4/618 – Bright nickel plated, clear coated
- 1-5/619 – Satin nickel plated, clear coated
- 20D/624 – Dark statuary bronze lacquered
- 2-6/625 – Bright chrome plated
- 26D/626 – Satin chrome plated
- 3-2/629 – Bright stainless steel
- 32D/630 – Satin stainless steel
- BSP – Black suede powder coat
- WSP – White suede powder coat
Attributes
Alternate Codes: 12-55-56-8715F-ETL-10BE LHR 36X84, 1255568715FETL10BELHR36X84
Category: Electrified Panic Devices, Panic Devices & Exit Alarms
Door Application: Panic Devices & Exit Alarms
Exit Device Options: Signal Switch in Rail
Exit Device Part Type: Motorized Electric Latch Retraction Kit, UL Fire Label
Finish Code: 613E
Finish Color: Dark Oxidized Satin Bronze
Function: Trim Always Operable
Handing: Left Handed Reverse
Series: 8700
Shipping Limitations: Some products exceed standard small package size regulations and may incur additional fees. Items measuring 84″ or more could require extra charges or LTL shipping. Please keep this in mind when ordering, and contact customer service for more details.